Deployment planning
4.4 C-PLUG (configuration plug)
SCALANCE S
Commissioning and Hardware Installation Manual, 05/2016, C79000-G8976-C266-06
29
Note
Reset to factory settings
If a C
-PLUG is plugged in when you reset to factory settings, the C-PLUG is erased.
Note
Setting the time-of-day after inserting a C-PLUG
After you have inserted the C
-PLUG in a new device, check the time-of-day on the device to
make sure the certificates are still valid.
Use of a C-PLUG that already contains configuration data
Use only C-PLUGs that are formatted for the relevant SCALANCE S device type. C-PLUGs
that have already been used in other device types and formatted for these device types must
not be used.
The following table shows which C-PLUG you can use for which SCALANCE S device type:
SCALANCE S device
type
C-PLUG formatted by
S602 V2
S612 V2
/
S613 V2
S602
V3
S602 ≥
V3.1 in
ghost
mode
S602 V4
S612
V3
S612
V4
S623
V3
S623
V4
S627-
2M V4
S602 V2
x
-
-
-
-
-
-
-
-
-
S612 V2 /
S613 V2
-
x
-
- -
-
- - - -
S602 V3
x
-
x
-
-
-
-
-
-
-
S602 ≥ V3.1 in ghost
mode
- - -
x
- - - - - -
S602 V4
x
-
x
x
x
-
-
-
-
-
S612 V3
-
x
-
-
-
x
-
-
-
-
S612 V4
-
x
-
-
-
x
x
-
-
-
S623 V3
-
-
-
-
-
-
-
x
-
-
S623 V4
-
-
-
-
-
-
-
x
x
-
S627-2M V4
-
-
-
-
-
-
-
-
-
x
x
C-PLUG can be used with the device type
-
C-PLUG cannot be used with the device type
Before you use a formatted C-PLUG for another device, you will need to reset the
SCALANCE S device to the factory settings by pressing the reset button and then download
the required project to the SCALANCE S device. The use of C-PLUGs that are formatted
without a module ID is possible without resetting to the factory settings.