Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
109
Command
Description
Comment
setec [event]
<E|D> <E|D>
<E|D> <E|D>
Specifies how an IE switch reacts to system events.
The following abbreviations are available for the event parameter:
CW
Cold/Warm start
LC
Link Change
AF
Authentication Failure
RA
RMON Alarm
PC
Power Change
RC
RM State Change
SC
Standby State Change
FC
Fault State Change
RS
STP/RSTP Change
LD
Loop Detection State Change
PA
Port Auth State Change
VE
VRRP State Change
(X414 only)
FO
Fiber Optic Diagnostics
If an event is specified, the configured actions are formed for each
event.
The four parameters that follow <E> or <D> configure the reactions
of the IE switch in the order:
E-mail
Trap
Entry in the log table
Entry on the Syslog server
Example:
setec LC E D D D
Only sends an E-mail if there is a Link Change.
Administrator
only.