Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
111
Figure 4-37 Agent Digital Input Configuration
Name
Here, you can assign a meaningful name for each digital input.
Syntax of the Command Line Interface
Table 4- 27 Agent Digital Input Configuration - CLI\AGENT\DIGIN>
Command
Description
Comment
info Shows the state of the digital inputs of the SCALANCE
X414-3E.
-
showdic Shows the configuration of the digital inputs of the
SCALANCE X414-3E.
-
setdic [input]
<E|D> <E|D>
<E|D> <E|D>
Sets the event configuration for the digital inputs in the
order: E-mail, trap, log table entry, entry on the Syslog
server. If no input is specified, the specified configuration
relates to all inputs.
Example:
setdic 5 E D E D
If input 5 is set, the SCALANCE X414-3E sends an E-
mail and makes an entry in the log table. No trap is
sent and no entry is made on the Syslog server.
Administrator only.
name <1 ... 8>
<string>
Assigns a symbolic name to a digital input. This name can
be a maximum of 64 characters long.
Administrator only.