Configuration using Web Based Management and Command Line Interface   
4.4 The Agent menu 
  SCALANCE X-300 / X-400 
122  Configuration Manual, 10/2014, C79000-G8976-C187-22 
 
Enter a key for the encryption. 
Permitted values for the key: an ASCII string with up to 11 characters or a hexadecimal 
string with up to 40 characters. 
 
Enable this function to send encrypted frames. 
 
Enter the interval at which the client sends requests to the time server and updates the 
system time. 
 
Enter the time after which a client queries the system time with the server following the first 
connection. 
Syntax of the Command Line Interface 
Table 4- 33  NTP Client Configuration - CLI\AGENT\TIME\NTP> 
Specifies the server number and the IP address of the NTP server. 
initint [1...10000]  Specifies the interval for querying the system time after the first 
connection. Permitted values: 1...10000 ms. 
Administrator only. 
interval [1...160]  Specifies the interval for querying and updating the system time. 
Permitted values: 1...160 s. 
Administrator only. 
secure <Server 
No.><KeyID><MD5|SHA>
Specifies the server number, the key ID, the algorithm and the key 
for secure transfer of the frames. 
Administrator only. 
Enables / disables NTP security.