Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
225
Tx-only: This port can only send LLDP frames.
Tx and Rx: This port can receive and send LLDP frames.
Disabled: This port can neither receive nor send LLDP frames.
Syntax of the Command Line Interface
Table 4- 71 Current Multicast Groups - CLI\SWITCH\LLDP>
Command
Description
Comment
info
Displays the current LLDP settings.
-
lldpport <mode> [ports] Changes the LLDP settings for a port. If no port is
specified, all ports are changed.
The <mode> parameter can have the following values:
rx
receive only
tx
send only
e
receive and send
d
neither receive nor send
Administrator
only.