Configuration using Web Based Management and Command Line Interface
4.2 The System menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
45
Restore Factory Defaults and Restart
Click this button to restore the factory defaults for the configuration. The protected defaults
are also reset. An automatic restart is triggered.
Note
By resetting all the defaults, the IP address is also lost. An IE
switch is then only accessible
using the Primary Setup Tool or the serial interface (IE
Switch X-400 only).
Syntax of the Command Line Interface
Table 4- 4 System Restart & Defaults - CLI>
Command
Description
Comment
restart Restarts the IE switch Administrator only.
This command can be executed
from within all menus.
Table 4- 5 System Restart & Defaults - CLI\SYSTEM>
Command
Description
Comment
defaults Restores the factory defaults. The protect-
ed settings are also reset. The device is
restarted.
Administrator only.
This command has the same effect
as clicking the
Restore Factory
Defaults and Restart
button in
WBM.
memreset Restores the factory defaults. The protect-
ed settings are retained. The device is
automatically restarted.
Administrator only.
This command has the same effect
as clicking the
Restore Memory
Defaults and Restart
button in
WBM.