Do you have a question about the Siemens SED2 and is the answer not in the manual?
Input Voltage | 380-480V AC |
---|---|
Current Rating | Depends on model |
Control Type | Digital |
Communication | PROFIBUS, PROFINET, Ethernet |
Communication Interface | RS485 |
Protection Features | Overcurrent, overvoltage, undervoltage, overtemperature, short circuit |
Operating Temperature | 0 to +45 °C |
Storage Temperature | +70 °C |
Describes the organization of the manual and symbols used throughout.
Explains the meaning of DANGER, WARNING, CAUTION, and NOTES notations.
Provides contact information for submitting feedback on the manual.
Lists other available SED2 VFD documentation for further information.
Diagram showing the AOP menu structure based on operating mode.
Critical information and cautions regarding AOP mounting, command source, and control buttons.
Details the initial power-up sequence, self-tests, and communication establishment.
Procedure for selecting the display language for the AOP interface.
Instructions on accessing and navigating the on-line help screens.
Describes controlling a single SED2 VFD with the AOP in Local mode.
Procedure for connecting and configuring multiple SED2 VFDs via RS-485 network.
Explains using the AOP as an RS-232/RS-485 converter for PC connectivity.
Defines user access levels (User Defined, Standard, Extended, Expert) for parameter editing.
Procedure for viewing and modifying standard SED2 VFD parameters.
Guide for viewing and editing indexed parameters within specific parameter groups.
Information on the AOP's capability to store and manage up to 10 parameter sets.
Procedure for editing parameter sets stored within the AOP's memory.
Instructions for editing internal AOP parameters, requiring expert access level.
Process for reading parameter sets from a SED2 VFD into the AOP.
Notification screen indicating the SED2 is performing a longer task.
Procedure for writing parameter sets from the AOP to a SED2 VFD.
Overview of AOP operating modes: Local, Master, Internal, Slave, PC Mode, Upload.
Details controlling a single SED2 VFD directly mounted to the AOP.
Describes controlling multiple SED2 VFDs individually via a network.
Explains simultaneous start/stop control of all networked SED2 VFDs.
Information on handling and acknowledging communication loss between AOP and SED2.
How the AOP monitors and displays the current status of the SED2 VFD and motor.
Process for checking SED2 VFD compatibility with the AOP.
Procedure for configuring the AOP's 7-day time-of-day on/off controller.
Accessing the Setup menu to personalize AOP characteristics.
Configuring AOP backlighting status and timer.
Adjusting the contrast level of the AOP display.
Enabling a large-number display mode for SED2 VFD frequency.
Selecting the cursor display type (underline or inverse-video).
Enabling or disabling the automatic display of help screens at startup.
Editing the custom welcome text displayed on the AOP at power-up.
Entering custom text strings for user-defined display messages.
Naming the ten AOP parameter sets for easier identification.
Setting the real-time clock for the AOP's timer functions.
Procedure for resetting AOP parameters, settings, and logs to default values.
Displays fault messages with identity, code, and explanation.
Displays warning messages with identity, code, and explanation.
How the AOP cycles through multiple fault messages.
How the AOP cycles through multiple warning messages.
How the AOP displays combined fault and warning messages.
Accessing the diagnostic menu for recent fault history.