Siemens SINAMICS G110D Specifications

General IconGeneral
Control MethodV/f control, vector control
Protection ClassIP20
Relative Humidity5% to 95% (non-condensing)
Communication InterfacesModbus RTU
Cooling MethodNatural convection
Storage Temperature-40°C to +70°C
Installation AltitudeUp to 1000 m
Input Voltage1AC 200-240 V ±10%
Frequency Range0 to 500 Hz

Summary

Fundamental safety instructions

General safety instructions

Essential safety rules and procedures for working with electrical devices.

Residual risks of power drive systems

Identifies potential hazards and residual risks associated with power drive systems.

Introduction

About this manual

Explains the purpose and target audience of the operating instructions.

Adapting the Inverter to the application

Describes how to configure the inverter for specific motor and application needs.

Description

Overview of SINAMICS G110D Inverters

Provides a general description of the SINAMICS G110D inverter series.

Components of the Inverter system

Details the different frame sizes and models of the SINAMICS G110D.

Connection

Procedure for installing the Inverter

Outlines the steps and prerequisites for installing the inverter.

Ambient operating conditions

Specifies temperature, humidity, and altitude derating requirements.

SINAMICS G110D Specifications

Lists technical specifications for output, input, and fuses.

Cables and connections

Details cable types, lengths, and connection specifications.

Commissioning

Typical commissioning scenarios

Outlines common methods for commissioning the inverter.

Restoring the factory settings

Describes how to reset the inverter parameters to their default factory values.

Commissioning with STARTER

Guides through the basic commissioning process using STARTER software.

Basic commissioning with IOP

Describes the step-by-step wizard for basic commissioning using the Intelligent Operator Panel.

Backup data and storage

Explains methods for backing up and transferring inverter parameter data.

Functions

Overview of Inverter functions

Provides a visual overview of the inverter's functional capabilities.

Inverter Control

Details how the inverter controls motor operation, focusing on digital input methods.

Motor control

Details V/f control methods and optimization for starting characteristics.

Protection functions

Outlines the inverter's built-in protective functions against overtemperature and overcurrent.

Service and maintenance

Behaviour of the Inverter when replacing components

Explains how the inverter behaves when components are replaced.

Repair switch

Explains the function and use of the repair switch for isolation.

Messages and fault codes

Fault codes

Lists common fault codes, their causes, and remedies.

LED States

Explains the meaning of the inverter's status LEDs.

Technical data

Technical data of the SINAMICS G110D

Provides detailed specifications for the inverter.

Pulse frequency and current reduction

Details how pulse frequency affects current output.

Appendix A

Electromagnetic compatibility

Discusses EMC compliance requirements and standards.

Standards

Lists relevant European directives and standards the product complies with.