Connection
4.7 SINAMICS G110D Specifications
SINAMICS G110D
42 Operating Instructions, 07/2016, FW V3.63, A5E36768472B AB
SINAMICS G110D Specifications
SINAMICS G110D specifications
Table 4- 1 Rated Output, Input and Fuses
0PE17-5AM0 A 0.75 1 2.3 2.0 10 803
3RV1021-1FA10
0PE21-5AM0 A 1.5 1.5 4.3 3.9 10 803
3RV1021-1JA10
0PE23-0AM0 A 3 4 7.7 7.0 16 805
3RV1021-4AA10
0PE24-0AM0 B 4 5 10.2 9.1 20 807
3RV1021-4BA10
0PE25-5AM0 C 5.5 7.5 13.2 12.2 20 807
3RV1031-4EA10
0PE27-5AM0 C 7.5 10 19 17.9 32 812
3RV1031-4FA10
Branch Circuit Protect (BCP)
The following information details the requirements for the Branch Circuit Protect (BCP) of the
SINAMICS G110D converter.
Table 4- 2 Non-semiconductor fuses according to IEC
Max current rating of
fuse (A)
SINAMICS G110D
SCCR with fuse
*Where “_” in the Circuit breaker No. can be replaced by “1” or “2”.