EasyManua.ls Logo

Siemens SIMATIC ET 200SP HA User Manual

Siemens SIMATIC ET 200SP HA
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SIMATIC
ET 200SP HA
F-AI 8xI 2-/4-wire HART HA
Equipment Manual
6DL1136-6AA00-0PH1
09/2021
A5E50557845-AA
Security information
1
Preface
2
Product overview
3
Connection
4
Parameters/address space
5
Applications of the F-I/O
module
6
Displays, alarms and
messages
7
HART function
8
Technical speci󹪝cations
9
HART operating data
records
A
Analog value
representation
B
Response times
C

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP HA

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP HA and is the answer not in the manual?

Siemens SIMATIC ET 200SP HA Specifications

General IconGeneral
CategoryI/O Systems
SystemSIMATIC ET 200SP HA
MountingDIN rail
Protection RatingIP20
Communication ProtocolPROFINET
RedundancyYes
Hot SwappingYes
ModularityModular
Power Supply24 V DC
Temperature Range-40 to 70 °C
Product TypeDistributed I/O
Number of I/O modulesUp to 64
Redundancy Typesystem redundancy
Operating Temperature-40 to 70 °C
Storage Temperature-40 to 70 °C
Relative Humidity5% to 95% (non-condensing)
Vibration ResistanceIEC 60068-2-6
Shock ResistanceAccording to IEC 60068-2-27
Mounting TypeDIN rail

Summary

Security information

Product overview

Properties of I/O module

Details the properties and features of the F-AI 8xI 2-/4-wire HART HA I/O module.

Parameters/address space

Module/channel parameters

Details module/channel specific parameters affecting module or channel configuration.

Explanation of the module/channel parameters

Provides detailed explanations for key module and channel parameters.

Address space

Details the allocation of input and output address space for the I/O module.

Applications of the F-I/O module

Application case 1: SIL3/Cat.3/PLd, 2-wire transmitter, 1oo1

Details wiring and parameter assignment for SIL3/Cat.3/PLd, 2-wire transmitter, 1oo1 application.

Application case 1a: SIL3/Cat.3/PLd, 2-wire transmitter, 1oo1 (high availability)

Details wiring and parameter assignment for redundant SIL3/Cat.3/PLd, 2-wire transmitter, 1oo1.

Application case 2: SIL3/Cat.3/PLd, 4-wire transducer, 1oo1

Details wiring and parameter assignment for SIL3/Cat.3/PLd, 4-wire transducer, 1oo1 application.

Application case 2a: SIL3/Cat.3/PLd, 4-wire transmitter, 1oo1 (high availability)

Details wiring and parameter assignment for redundant SIL3/Cat.3/PLd, 4-wire transmitter, 1oo1.

Application case 3: SIL3/Cat.4/PLe, 2- or 4-wire transducer, 1oo2

Details wiring and parameter assignment for SIL3/Cat.4/PLe, 2/4-wire transducer, 1oo2 application.

Requirements placed on sensors for fail-safe modules

Outlines specific requirements for sensors used in fail-safe applications.

Displays, alarms and messages

Diagnostic messages

Explains diagnostic messages, their meanings, causes, and possible remedies.

HART function

Technical specifications

Technical specifications

Provides detailed technical data, electrical specifications, and environmental conditions.

Related product manuals