EasyManua.ls Logo

Siemens SIMATIC ET 200eco PN User Manual

Siemens SIMATIC ET 200eco PN
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ET 200eco PN
___________________
___________
___________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
SIMATIC
Distributed I/O
ET 200eco PN
Operating Instructions
08/2016
A5E01250250
-AJ
Preface
Product overview
1
Installing
2
Wiring
3
Configuring
4
Commissioning
5
Maintenance
6
Interrupt, error, and system
messages
7
General technical data
8
I/O device digital
inputs/digital outputs
9
I/O device analog
input/analog output
10
IO-Link Master
11
Terminal block and voltage
distributor
12
Signal names
A
Article numbers
B
Dimensional drawings
C
Connection examples
D
I/O address space
E
Response times for analog
input device and output
device
F
Fail-safe shutdown of ET
200eco PN standard
modules
G
Open Source Software
H

Table of Contents

Other manuals for Siemens SIMATIC ET 200eco PN

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200eco PN and is the answer not in the manual?

Siemens SIMATIC ET 200eco PN Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC ET 200eco PN
CategoryI/O Systems
LanguageEnglish

Summary

Preface

Purpose of the manual

Explains the manual's goal to enable operation of ET 200eco PN on PROFINET IO.

Basic knowledge required

Outlines prerequisites, assuming general automation engineering knowledge.

Scope of this manual

Defines the manual's applicability to the ET 200eco PN distributed I/O device.

Changes compared to the previous version

Lists modifications from the prior manual version, including IO-Link master and standards.

Standards and certifications

Guides users to find standards and approvals for the ET 200eco PN I/O system.

Scope of information

Lists additional required documentation for operating the ET 200eco PN.

Product overview

Distributed I/O device – Overview

Introduces distributed I/O systems and their application areas in automation.

ET 200eco PN Distributed I/O Device

Defines the ET 200eco PN as a compact PROFINET IO device with specific protection degrees.

Components of ET 200eco PN

Provides an overview of the main components of the ET 200eco PN, including LEDs and connectors.

IO-Link Master

Explains the concept of IO-Link Masters and their connection to sensors/actuators.

Installing

Two installation variants

Describes the two installation methods: with and without a mounting rail.

Installation without mounting rail

Details the simple installation procedure for mounting the I/O device directly onto a solid base.

Installation with mounting rail

Explains how to install the I/O device using a mounting rail, including preparation and attachment.

Mounting position, mounting dimensions

Specifies that the ET 200eco PN can be mounted in any position and provides mounting dimensions.

Installing the terminal block

Describes the properties, requirements, and procedure for installing the terminal block.

Replacing labels

Details the process for identifying I/O devices and connectors using labels and how to replace them.

Removing ET 200eco PN

Provides instructions on how to safely remove the ET 200eco PN device from its installation.

Wiring

General rules and regulations for operating an ET 200eco PN

Outlines essential rules for operating the ET 200eco PN in various plant applications.

Operating ET 200eco PN on grounded mains

Discusses protection against electrical interference and grounding requirements for the device.

Electrical configuration of ET 200eco PN

Explains the electrical isolation features within the ET 200eco PN configuration.

Technical specifications of the lines

Covers line protection requirements and the influence of cable length on supply voltage.

Wiring the ET 200eco PN

Details the process of wiring the ET 200eco PN to functional earth (FE) and wiring I/O devices.

Pin assignment of connectors

Lists the pin assignments for PROFINET connectors, voltage infeed, and various I/O types.

Wiring the terminal block

Explains the tools required and the procedure for wiring the terminal block and its connectors.

Wiring the voltage distributor

Demonstrates how to wire the voltage distributor with connected I/O devices, including pin assignments.

Looping PROFINET and the supply voltage

Describes the process of looping PROFINET and supply voltage through the I/O device.

Configuring

Configuring ET 200eco PN

Guides users on configuring the ET 200eco PN using STEP 7, including GSD file installation.

Configuring an IO-Link master

Provides steps for configuring IO-Link Masters (6ES7148-6JA00-0AB0 and 6ES7148-6JD00-0AB0) using HW Config and S7-PCT.

Device names for ET 200eco PN

Explains how to assign device names (MAC addresses) to ET 200eco PN devices for PROFINET IO addressing.

Ports of ET 200eco PN

Details how to configure the ports of the ET 200eco PN in HW Config, including port diagnostics.

Isochronous real-time communication

Explains synchronized communication protocol for cyclic exchange of IRT data between PROFINET devices.

Prioritized startup

Describes PROFINET functionality for accelerating the startup of IO Devices for RT and IRT communication.

Device replacement without programming device

Explains how IO Devices with this function can be replaced easily without a programming device.

Media redundancy

Discusses the function for ensuring network and system availability through redundant transmission links.

Reset to factory settings (PROFINET)

Details the procedure and consequences of resetting the ET 200eco PN to factory settings.

SNMP

Explains the support for SNMP Ethernet service for diagnostics and parameter assignment.

Commissioning

Commissioning ET 200eco PN

Outlines the procedure for commissioning the ET 200eco PN on an IO Controller, including prerequisites.

Maintenance

Replacing the fuse

Provides step-by-step instructions for replacing the fuses in the terminal block.

Online firmware update by means of STEP 7 Manager

Guides users on updating the ET 200eco PN firmware using STEP 7 Manager.

Acyclic data exchange with the IO-Link library

Explains the use of "IO_LINK_MASTER" and "IO_LINK_DEVICE" function blocks for acyclic data exchange.

Exchange object

Describes the process when I/O devices are exchanged using the "Exchange object" function in HW Config.

Interrupt, error, and system messages

Interrupts of ET 200eco PN

Explains how the IO Device generates interrupts in response to specific error events.

Maintenance interrupts

Lists available maintenance interrupts for the ET 200eco PN, such as sync mismatch and frame drops.

Diagnostics by means of LED display

Details how to diagnose issues using the LED displays on I/O devices, IO-Link Masters, and voltage distributors.

Diagnostics messages of the I/O devices

Explains actions triggered by diagnostics messages and how to read diagnostic data.

Channel diagnostics

Provides information on the structure of diagnostics data records specific to ET 200eco PN devices.

Error classes for I/O devices

Lists error types for I/O devices, including digital and analog inputs/outputs, with remedies.

General technical data

Standards and certifications

Details compliance with standards like IEC 61131-2, PROFINET IO, CE marking, ATEX, RCM, and cULus.

EMC compatibility, shipping and storage conditions

Covers electromagnetic compatibility, pulse-shaped disturbances, and shipping/storage requirements.

Mechanical and climatic environmental conditions

Specifies operating temperature ranges and mechanical environmental conditions for the devices.

Specification of dielectric tests, protection class, degree of protection, and rated voltage of ET 200eco PN

Details dielectric tests, IP ratings, pollution degrees, and rated voltage specifications.

I/O device digital inputs/digital outputs

I/O device digital inputs

Provides properties, pin assignment, block diagrams, and technical data for digital input devices.

I/O device digital outputs

Details properties, pin assignment, block diagrams, and technical data for digital output devices.

I/O device digital inputs/digital outputs

Outlines properties, pin assignment, and technical data for parameterizable digital input/output devices.

I/O device analog input/analog output

I/O device analog input

Covers properties, input ranges, pin assignments, block diagrams, and technical data for analog input devices.

I/O device analog output

Details properties, output ranges, pin assignments, block diagrams, and technical data for analog output devices.

IO-Link Master

IO-Link Master (6ES7148-6JA00-0AB0)

Describes properties, general pin assignment, block diagrams, and technical data for this IO-Link Master.

IO-Link Master (6ES7148-6JD00-0AB0)

Outlines properties, general pin assignment, block diagrams, and technical data for this IO-Link Master.

Parameters for IO-Link Master

Lists parameters for configuring the IO-Link Master, including diagnostics and response settings.

Functions

Explains operating modes (IO-Link, DI, DQ, Disabled) and Port Qualifier Information (PQI).

Terminal block and voltage distributor

Terminal block

Details the properties, pin assignment, block diagram, and technical data of the terminal block.

Voltage distributor

Covers the properties, pin assignment, block diagram, and technical data of the voltage distributor.

Signal names

Signal names of the I/O devices

Provides a list of signal names for digital inputs/outputs and analog inputs/outputs.

Article numbers

I/O devices

Lists article numbers for various I/O devices, including digital, analog, and IO-Link master modules.

Accessories for I/O devices

Provides article numbers for accessories such as voltage distributors, terminal blocks, and cables.

Dimensional drawings

Dimensional drawing of the I/O devices of 30 mm width

Shows the dimensional drawings for ET 200eco PN I/O devices with 30 mm width.

Dimensional drawing of the I/O devices of 60 mm width

Displays dimensional drawings for ET 200eco PN I/O devices with 60 mm width.

Dimensional drawing of the voltage distributor

Provides the dimensional drawing for the voltage distributor PD DC 24V 1x7/8" 4xM12.

Dimensional drawing of the terminal block

Shows the dimensional drawings for the terminal block, both separately and installed.

Dimensional drawing of the mounting rail

Illustrates the dimensional drawings of the mounting rail for different I/O device widths.

Connection examples

Connection of resistance thermometers to the analog inputs

Illustrates connection examples for 2-, 3-, and 4-conductor resistance thermometers to analog inputs.

Connection of thermocouples to the analog inputs

Shows connection examples for thermocouples with different reference junction compensation methods.

I/O address space

I/O device 8 DI DC 24V 4×M12

Details the address space assignment in the process image inputs for this device.

I/O device 8 DI DC 24V 8×M12

Explains the address space assignment in the process image inputs for this device.

I/O device 16 DI DC 24V 8×M12

Covers the process image output address space assignment for this device.

I/O device 8 DO DC 24V/1,3A 4×M12

Shows the process image output address space assignment for this device.

I/O device 8 DO DC 24V/0,5A 4×M12

Illustrates the process image output address space assignment for this device.

I/O device 8 DO DC 24V/1,3A 8×M12 and 8 DO DC 24V/2,0A 8×M12

Details the process image output address space assignment for these devices.

I/O device 16 DO DC 24V/1,3A 8×M12

Explains the process image output address space assignment for this device.

I/O device 8 DIO DC 24V/1,3A 8×M12

Covers the process image input address space assignment for this device.

IO-Link Master 4 IO-L + 8 DI + 4 DO DC 24V/1,3A 8×M12

Describes address space selection for inputs and IO-Link channels.

IO-Link Master 4 IO-L 4×M12

Shows address space assignments in SIO mode for inputs and outputs.

IO-Link Master 4 IO-L 4×M12

Illustrates address space assignments in IO-Link mode, including PQI byte.

Response times for analog input device and output device

Response times for analog input device

Explains conversion time, cycle time, and settling time for analog input channels.

Response times for analog output device

Details conversion time, cycle time, settling time, and response time for analog output channels.

Fail-safe shutdown of ET 200eco PN standard modules

Back-up oriented shutdown of ET 200eco PN standard modules

Describes how to safely shut down ET 200eco PN standard modules in a fail-safe manner.

Open Source Software

Open Source Software

Provides information on license conditions, disclaimers, and copyright notices for Open Source Software used in the product.

Related product manuals