Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C

Summary

Preface

Security Information

Information on industrial security measures and recommendations for product updates.

Documentation Guide

Basic Information

Describes the system manual for configuration, installation, wiring, and commissioning.

TIA Selection Tool

Tool for selecting, configuring, and ordering devices for Totally Integrated Automation (TIA).

Product Overview

Module Properties

Lists technical properties like voltage range, retentive storage, and recording capabilities.

Module Area of Application

Discusses the importance of energy efficiency and applications of the AI Energy Meter HF.

Wiring

Supported Connection Types

Lists supported connection types (3P4W1, 3P4W, 2P3W, etc.).

Configuration / Address Space

Module Configuration

Explains how to configure the AI Energy Meter HF using STEP 7 or GSD files.

Module Version Selection

Discusses different module versions and how they affect measured value reading.

Quick Start

Reading Measured Values Basics

Explains methods for reading values: cyclic user data and acyclic data records.

Energy Counters

Evaluate Measured Values for Energy

Describes two ways to evaluate measured values: RDREC instruction and user data variants.

Setting Energy Counter Start Values

Explains how to start counters with new values using data record DS 143.

Operating Hours Counter

Evaluating Operating Hours Counters

Explains two ways to evaluate counters: data records (RDREC) and user data variants.

Limit Monitoring

Limit Monitoring Functionality

Explains monitoring of parameterizable limits for measured variables and data record 150.

Delay Time and Hysteresis Settings

Configuration options for delay time and hysteresis to filter fluctuations.

Minimum and Maximum Values

Min/Max Value Tracking

Explains determination of highest/lowest measured values, stored retentively, and readable via data records.

Power Quality Analysis Functions

Harmonics Analysis

Details determining effective values for current/voltage up to 40th harmonic.

Parameters

AI Energy Meter HF Parameters

Explains configuring parameters with STEP 7, GSD files, and in RUN mode.

Interrupts/Diagnostic Alarms

LED Status and Error Display

Explains LED display (DIAG, Error, PWR, Status) and their meanings.

Diagnostic Error Types

Table detailing diagnostic messages, error codes, meanings, and solutions.

Technical Specifications

AI Energy Meter HF Technical Specifications

Shows technical specs as of 07/2018 and provides an Internet link for updated data.

Accuracy Classes

Lists accuracy classes for various measured variables like voltage, current, and power factor.

Parameter Data Records

Parameter Data Record Configuration

States that parameter data records have identical structure regardless of PROFIBUS DP or PROFINET IO configuration.

DS 128 Structure for Entire Module

Shows structure of data record 128, including header information.

Error Code in STATUS Parameter (Hexadecimal)

Table of module-specific error codes and solutions for parameter data record 128.

Measured Variables

Measured Variables Overview

Table providing an overview of measured variables used in data records and user data.

Module Versions

Module Version 2 I / 2 Q

Describes the module version with 2 bytes input and 2 bytes output user data.

Module Version 32 I / 20 Q

Describes module version occupying 32 bytes input and 20 bytes output user data.

User-specific Module Version

Explains module version occupying 16 to 256 bytes input user data, configurable structure.

User Data Variants

User Data Variants Overview

Table showing existing user data variants and their IDs.

Measured Value Data Records

Measured Value Data Records Overview

Lists all measured value data records (DS 142-170) that can be read acyclically using RDREC.

DS 142 Base Measurements Version 2

Shows structure of DS 142, version 2, listing measured variables and their IDs.

DS 149 Phase L3 Version 0 Structure

Shows structure of DS 149, version 0, listing measured variables and their IDs.

Structure for Energy Counters (DS 143)

Details data record 143 for energy meters, including actions like reset and reading values.

Measured Value Data Record for Maximum Values (DS 144) Version 1

Shows structure of DS 144, version 1, listing measured variables and their default values.

Measured Value Data Record for Minimum Values (DS 145) Version 1

Shows structure of DS 145, version 1, listing measured variables and their default values.

Tips and Tricks

Processing Energy Data

Shows how to process and visualize energy data via an application example.

Related product manuals