How to fix Siemens SIMATIC ET 200S I/O Systems ET 200S when it does not start up due to a configuration error?
J
James RiceJul 25, 2025
If your Siemens I/O Systems ET 200S fails to start due to a configuration error, it might be caused by multiple power module entries ending in '...O' or '...SO' in the ET 200S configuration. To resolve this, review and correct the configuration within HWCONFIG.
J
John ChristensenAug 2, 2025
What to do if there is no clocked signal detection/output in Siemens SIMATIC ET 200S I/O Systems?
R
rrhodesAug 2, 2025
If there is no clocked signal detection/output in your Siemens I/O Systems, it might be due to the wrong process image partition being used, resulting in a negative RET_VAL with SFCs 126/127. Verify that the same process image partition is used in the OB 61 user program (or up to OB 64) when SFCs 126/127 are called and in the configuration of the DP master/DP slave.
D
davidrichardsAug 10, 2025
Why are the equidistance times too long in Siemens SIMATIC ET 200S?
W
watsoncherylAug 10, 2025
If the equidistance times are too long in your Siemens I/O Systems, it could be that the input delays of the HIGH FEATURE digital input modules are not optimally set. To resolve this, decrease the input delay of the HIGH FEATURE digital input modules.
B
bmcguireAug 17, 2025
How to fix station failure of the Siemens ET 200S I/O Systems?
D
Dr. Amber GainesAug 17, 2025
Station failure of the Siemens ET 200S I/O Systems can occur due to errored clocking (more than 10 lost or interrupted cycles). To fix this, check the parameter assignment.