Digital Electronic Modules
11-24
ET 200S Distributed I/O System
EWA-4NEB 780602402-12
Connection assignment
The following table shows the terminal assignment of the 4DI 24 VDC High
Feature for the various terminal modules:
Table 11-8 Terminal assignment of the 4DI 24 VDC High Feature
View
Terminal assignment Remarks
VDC
VDC
AUX1 (e.g. M)
2
3
4
6
7
8
1
5
AUX1 (e.g. M)
2-wire
TM-E15S24-A1 and 4DI 24 VDC High Feature
CH1CH0
DI
1
DI
0
DI
2
DI
3
CH2 CH3
AA
Channel 0: Terminals 1
and 3
Channel 1: Terminals 5
and 7
Channel 2: Terminals 2
and 3
Channel 3: Terminals 6
and 7
DI: Input signal
24 VDC: Sensor supply
VDC
2
3
4
6
7
8
1
5
2-wire
TM-E15S24-01 and 4DI 2 4 VDC High Feature
CH1CH0
DI
1
DI
0
DI
2
DI
3
CH2 CH3
VDC
VDC
VDC
Channel 0: Terminals 1
and 3
Channel 1: Terminals 5
and 7
Channel 2: Terminals 2
and 4
Channel 3: Terminals 6
and 8
DI: Input signal
24 VDC: Sensor supply
2
3
6
7
1
5
TM-E15S23-01 and 4DI 2 4 VDC High Feature
VDC
CH0
DI
0
DI
2
CH2
CH1
DI
1
DI
3
CH3
VDC
2-wire
Channel 0: Terminals 1
and 3
Channel 1: Terminals 5
and 7
Channel 2: Terminals 2
and 3
Channel 3: Terminals 6
and 7
DI: Input signal
24 VDC: Sensor supply