Interrupts/diagnostic alarms
14.4 Diagnostics response
Analog input module AI Energy Meter 480VAC/CT HF (6ES7134-6PA00-0CU0)
Manual, 07/2018, A5E42674880-AA
113
14.4
Diagnostics response
Diagnostics response
This section describes the response of the AI Energy Meters HF when diagnostics
information is reported.
Measured values in the case of diagnostics
Even in the case of diagnostics, measured values continue to be displayed as long as they
can still be acquired. If measured values cannot be measured or calculated, "0" is displayed.
Low limit for current measurement undershot (zero suppression)
If the supplied current is less than the configured "Low limit for current measurement"
parameter, the current measurement and all dependent variables are suppressed and set to
"0".
If current falls below the low limit for the current measurement, the following measured
values and derived variables of the affected phase are reset.
Effective current value
Active power
Reactive power
Apparent power
Phase angle
Power factor
A moving mean value is formed from the power values and they only become "0" after a
corresponding time. The energy meters for active, reactive and apparent energy as well as
the operating hours counters do not count any longer.
If the secondary current fed in at the channel is higher than 12 A, the module changes to
limitation and the current measurement value of the current and all dependent variables are
set to "0".
Input data to "0"
If the AI Energy Meter HF is no longer recognized by the interface module (for example,
because it is defective or not plugged in), all input data are set to "0".

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C

Related product manuals