Parameter assignment
SIMATIC 3964R protocol for Windows 9x/XP/7
12
Installation Manual, 01/2013, J31069-D0131-U001-A2-7218
3. Enter the name of the interface in the "Name" input box.
The name must match the name specified in the device manager for the connected
hardware (integrated serial interface or external adapter, e.g. USB).
4. Select the "Apply configuration immediately" check box to adopt all the data immediately
in the configuration.
Close and open the relevant port using the application to adopt the data (e.g. if you
change the baud rate). Otherwise, only the data that does not relate to interface
parameters will be adopted (e.g. timeout times).
5. Click "OK" to apply your changes.
By clicking the "Reset" button, you reset the parameters to the values that were valid when
the configuration program was called. By clicking the "Default" button, you reset the
parameters to the original data written to the 3964R as default.
The maximum length for the send and receive buffer is 65536 bytes.
In the "# send repeats" input box, you specify the number of repetitions to be made following
a NAK (Negative Acknowledge or parity error). In the "# send initiation repeats" input box,
you specify the number of repetitions to be made following an STX (frame start / when the
communications partner does not respond).

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals