Programming interface
4.1 Functions of the serial interface
SIMATIC 3964R protocol for Windows 9x/XP/7
14
Installation Manual, 01/2013, J31069-D0131-U001-A2-7218
Notes
If "COM_OPEN_STD_PUF" is transferred as the buffer size, the buffer size from the
parameter assignment dialog is adopted.
The returned handle must be transferred as a parameter with all further calls.
Each buffer can hold several frames at the same time. The number is restricted only by
the total of the lengths of all buffered frames.
ComRead
comInt
ComRead
(int com_handle,
void *read_data,
int read_number,
long options)
This function is used for the blocking receipt of frames.
Parameter
com_handle interface handle from ComOpen
read_data Pointer to the receive buffer of the caller
read_number Length of the receive buffer
options Not used
Return value
≥ 0 Number of bytes read (≙ frame length)
< 0 possible error message:
COM_HANDLE_FALSE
COM_2SMALL
COM_READ_ERROR
Notes
The call blocks if no frame is present. No timeout parameter is intended.
This call fetches incoming frames from an internal buffer. The actual receive routine is
asynchronous.

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals