EasyManuals Logo

Siemens SIMATIC Ident Installation Manual

Siemens SIMATIC Ident
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Programming interface
4.1 Functions of the serial interface
SIMATIC 3964R protocol for Windows 9x/XP/7
22
Installation Manual, 01/2013, J31069-D0131-U001-A2-7218
ComWriteConfig
comInt
ComWriteConfig
(LPCSTR devName,
devConfig_p conf,
BOOL force)
This function writes the configuration data for a specified port to the registry. The port does
not need to be opened.
Parameter
devName Interface name as string
possible values: "COM1 ... COM255"
conf Pointer to configuration variable
force Force the immediate adoption of the configuration
Return value
0 Function successfully completed
< 0 possible error message:
COM_REGISTRY
COM_NO_CONFIG
Notes
If the "force" parameter is set to "TRUE", the configuration data is adopted immediately even
if the interface is already open. If necessary, the interface is closed to allow this and then
opened again.

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals