Chapter 6
Certification
RUGGEDCOM RSG907R
Installation Guide
36 CSA/Sira
CAN/CSA-C22.2 No. 60079-0:15
Explosive Atmospheres – Part 0: Equipment – General Requirements
CAN/CSA-C22.2 No. 60079-15:16
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Construction, Test and Marking of Type of
Protection "n" Electrical Apparatus
ANSI/UL 60950-1-2014
Information Technology Equipment – Safety Part 1: General Requirements
ANSI/ISA-12.12.01-2015
Non-Incendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazardous
(Classified) Locations
ANSI/UL 60079-0:13
Electrical Apparatus for Explosive Gas Atmospheres – Part 0: General Requirements
ANSI/UL 60079-15:13
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Type of Protection "n"
The device is marked with a CSA symbol that indicates compliance with both Canadian and U.S. requirements.
C US
It is specifically approved for use in Division 2 and Zone 2 hazardous locations with the following markings:
Class I, Division 2, Groups A, B, C, D T4
Ex nA nC IIC T4 Gc
Class I, Zone 2, AEx nA nC IIC T4 Gc
This device meets the requirements of the following International standards under certificate IECEx CSA
18.0007X:
IEC 60079-0:2011
Explosive Atmospheres – Part 0: Equipment – General Requirements
IEC 60079-15:2010
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Construction, Test and Marking of Type of
Protection "n" Electrical Apparatus.
It is specifically approved for use in Zone 2 hazardous locations with the following markings:
Ex nA nC IIC T4 Gc
Section6.1.2
CSA/Sira
When marked with the following ATEX marking, this device is approved for use in Zone 2 hazardous locations
under certificate Sira 18ATEX4069X.
NOTE
For the maximum ambient temperature, refer to the hazardous location label affixed to the device.

Other manuals for Siemens SIMATIC NET RUGGEDCOM RSG907R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET RUGGEDCOM RSG907R and is the answer not in the manual?

Siemens SIMATIC NET RUGGEDCOM RSG907R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET RUGGEDCOM RSG907R
CategorySwitch
LanguageEnglish

Related product manuals