Security recommendations
SCALANCE W774-1 /W734-1
10 Operating Instructions, 07/2020, C79000-G8976-C325-14
List of available services
The following is a list of all available services and their ports through which the device
can be accessed.
The table includes the following columns:
Service
The services that the device supports
Default port status
This is the status of the port in the delivery state (factory setting).
Configurable port/service
Indicates whether the port number or the service can be configured via WBM / CLI.
Authentication
Specifies whether the communication partner is authenticated.
If optional, the authentication can be configured as required.
Encryption
Specifies whether the transfer is encrypted.
If optional, the encryption can be configured as required.
Service Protocol/port
number
Default port
status
Configurable
Authentication Encryption
Port
Service
DHCP client
UDP/68
Outgoing only
--
--
--
DHCP server
UDP/67
Closed
--
--
--
DNS client
TCP/53
UDP/53
Outgoing only
--
--
--
EthernetIP
TCP/44818,
UDP/2222
UDP/44818
Closed
--
--
--
HTTP
TCP/80
Open
--
HTTPS
TCP/443
Open
NTP Client
UDP/123
Outgoing only
--
--
PROFINET
UDP/34964
UDP/49154
UDP/49155
Open
--
--
--
RADIUS
UDP/1812
Closed
--
Remote Capture
TCP/2002
Closed
--
--
--
SFTP client
TCP/22
Closed
SMTP client
TCP/25
Closed
--
--
SNMPv1/V2c
UDP/161
Open
--
--
SNMPv3
UDP/161
Open
Optional
Optional
SNMP traps
UDP/162
Outgoing only
--
--
--
SNTP Client
UDP/123
Outgoing only
--
--
SSH
TCP/22
Open