Mounting 
 
 
CAUTION 
Minimum distance to antennas 
Fit the device so that there is a minimum clearance of 20 cm between antennas and 
persons. 
 
WARNING 
If a device is operated in an ambient temperature of more than 50 °C, the temperature 
of the device housing may be higher than 70 °C. The device must therefore be 
installed so that it is only accessible to service personnel or users that are aware of the 
reason for restricted access and the required safety measures at an ambient 
temperature higher than 50 °C. 
 
 
WARNING 
When used in hazardous environments corresponding to Class I, Division 2 or Class I, 
Zone 2, the device must be installed in a cabinet or a suitable enclosure. 
General notes on use according to ATEX and IECEx 
 
 
 
WARNING 
Requirements for the cabinet/enclosure 
To comply with EC Directive 2014/34 EU (ATEX 114) or the conditions of IECEx, this 
enclosure or cabinet must meet the requirements of at least IP54 (in compliance with 
EN 60529) according to EN 60079-7.