Description of the device
3.6 Reset button
SCALANCE W774-1 /W734-1
Operating Instructions, 07/2020, C79000-G8976-C325-14
25
Functions of the reset button
The reset button has the following functions:
Restart of the device
To restart the device, press the Reset button briefly.
Note
If you make changes to the c
onfiguration and restart immediately afterwards with the
reset button, the changes may be lost. If you restart the device using the WBM (menu
command "System > Restart") or using the CLI (command "restart" in the Privileged
EXEC
Modus), the configuration changes are always retained.
Upkeep and maintenance
Loading new firmware
If the "Load & Save" menu command of Web Based Management is unsuccessful, the
reset button can be used to load new firmware. This situation can occur if there is a
power outage during the normal firmware update. You will find further information in
the configuration manual in Downloading new firmware using TFTP without WBM and
CLI.