2 Engineering
Securely Connecting RTU3041C to TeleControl Server Basic
Entry ID: 109739240, V3.0, 07/2021
55
© Siemens AG
2021 All rights reserved
Programming SMS transmission
24. Add a new network.
24
25. Assign the name "Send SMS" to the network.
25
26. Add a new function block (FB1).
26
27. Select "Send SMS" as the function.
28. Interconnect the parameters as follows:
Trigger: critFillLevel (DM1)
Send immediately: True
Recipient: Administrator SMS
Text: critLevelReached
27
28
28
29. Add a new function block (FB2) below it.
29