Configuration and operation   
5.11 STEP 7 configuration of individual parameters 
  CP 1243-1 PCC 
44  Operating Instructions, 02/2015, C79000-G8976-C384-01 
 
Ethernet interface (X1) > Advanced options 
TCP connection monitoring 
The setting made here applies globally to all TCP connections of the CP. 
Note the option of overwriting the value configured here for individual operation centers, refer 
to the section Operation center1 or Operation center2 (Page 45). 
TCP connection monitoring time 
If there is no data traffic within the connection monitoring time, the CP sends a keepalive to 
the communications partner.  
●  Permitted range: 0 ... 65535 s 
●  Default setting: 180 s; if you enter 0 (zero), the function is deactivated. 
The monitoring time is configured for the Ethernet interface as the default for all TCP 
connections. The default value can be adapted individually for each connection in "Operation 
center". 
TCP keepalive monitoring time 
After sending a keepalive, the CP expects a reply from the communications partner within 
the keepalive monitoring time. If the CP does not receive a reply within the configured time, it 
terminates the connection.  
●  Permitted range: 0 ... 65535 s 
●  Default setting: 1 s; if you enter 0 (zero), the function is deactivated. 
The monitoring time is configured for the Ethernet interface as the default for all TCP 
connections. The default value can be adapted individually for each connection in "Operation 
center". 
 
Operation center 
Operation center 
● 
 
Selecting the option enables communication with the configured operation center on the 
CP. You have option of configuring two operation centers. 
● 
 
The Operation center number in this parameter group is set by the system. It is required 
for data point configuration.