Technical specifications
CPU 1512C-1 PN (6ES7512-1CK00-0AB0)
Manual, 09/2016, A5E35306440-AB
131
32 KB; all inputs are within the process image
32 KB; all outputs are within the process image
per integrated IO subsystem
Inputs (volume)
8 KB
Outputs (volume)
8 KB
Inputs (volume)
8 KB
Outputs (volume)
8 KB
Number of process image partitions, max.
Number of distributed IO systems
32; a distributed IO system is understood to
mean the integration of distributed I/O via
PROFINET or PROFIBUS communication mod-
ules as well as the connection of I/O via AS-i
master modules or links (e.g. IE/PB link)
6; a total of up to 6 CMs/CPs (PROFIBUS,
PROFINET, Ethernet) can be inserted
6; a total of up to 6 CMs/CPs (PROFIBUS,
PROFINET, Ethernet) can be inserted
The number of connectable PtP CMs is only
limited by the number of available slots
6 wk; at 40 °C ambient temperature, typ.