Maintenance and service
5.3 Adapting a project (Upgrading the project / Replacing the SIMOTION controller)
SIMOTION D410
Commissioning Manual, 02/2012
173
The following types of data can be backed up:
Remanent global device variables and unit variables, as well as TO retain data (V4.1 and
higher) that are located in the FRAM of the control
Data saved with _saveUnitDataSet or _exportUnitDataSet, and which are located on the
CompactFlash Card
Note
When performing an upgrade with a firmware version that is ≥ V4.1, this function is only
required for backing up and restoring unit data sets that have been created using
_saveUnitDataSet.
Retain and unit data (saved with _exportUnitDataSet) remain valid even after a version
upgrade.
SIMOTION retain data can also be easily backed up to a memory card without the use of
SIMOTION SCOUT. For this purpose, use:
The _savePersistentMemoryData function or
A SIMOTION D410 service selector switch, or IT DIAG.
For information on this, refer to the section titled Diagnostic data and non-volatile
SIMOTION d
ata (Page 201).

Table of Contents

Other manuals for Siemens SIMOTION D410 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 DP and is the answer not in the manual?

Siemens SIMOTION D410 DP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410 DP
CategoryControl Unit
LanguageEnglish

Related product manuals