Faults and Alarms 10.99
6SE7087-6KP50 Siemens AG
12-6 Operating Instructions SIMOVERT MASTERDRIVES
Number / Fault Cause Counter-measure
F053
Parameter fault in
follow-up task
After changes have been made to parameters,
a fault has occurred during the calculation of
dependent parameters.
No remedy
F054
Encoder board
initialization fault
A fault has occurred during initialization of the
encoder board.
Fault value r949:
1: Board code is incorrect
2: TSY not compatible
3: SBP not compatible
4: SBR not compatible
5: SBM not compatible
6: SBM initialization timeout
7: Board double
20: TSY board double
21: SBR board double
23: SB board three-fold
24: SBP board three-fold
30: SBR board slot incorrect
31: SBM board slot incorrect
32: SBP board slot incorrect
40: SBR board not present
41: SBM board not present
42: SBP board not present
50: Three encoder boards
60: internal fault
F056
SIMOLINK telegram
failure
Communication on the SIMOLINK ring is
disturbed.
- Check the fiber-optic cable ring
- Check whether an SLB in the ring is without
voltage
- Check whether an SLB in the ring is faulty
- Check P741 (SLB TlgOFF)
F058
Parameter fault
Parameter task
A fault has occurred during the processing of a
parameter task.
No remedy
F059
Parameter fault after
factory setting/init.
A fault has occurred in the initialization phase
during the calculation of a parameter.
The number of the inconsistent parameter is
indicated in fault value r949. Correct this
parameter (ALL indices) and switch voltage off
and on again. Several parameters may be
affected, i.e. repeat process.
F060
MLFB is missing during
initial loading
Is set if parameter P070 is at zero when
INITIAL LOADING is exited.
Enter correct MLFB after acknowledging the
fault (power section, initial loading)
F061
Incorrect
parameterization
A parameter which has been entered during
drive setting is in the non-permissible range.
The number of the inconsistent parameter is
indicated in fault value r949 (e.g. motor
enocder = pulse encoder in the case of
brushless DC motors) -> correct this
parameter.
F063
PIN is missing
The synchronization or positioning technology
functions have been activated without an
authorization being present (PIN)
- Deactivate synchronization or positioning
- Enter the PIN (U2977)