Requirements
Connection Establishment to SINAMICS S120
SINAMICS S120 at Technology CPU  Entry ID: 21767896 
 
V1.0 Edition 10/28/05  14/58
 
Copyright © Siemens AG 2005 All rights reserved 
SINAMICS S120 und Technologie-CPU V2.0-SP1__05-10-28_13-20_e.doc 
 
Table 3-2  Configuration of the hardware components in HW Config 
No.  Instruction  Note 
1.  
In the STEP 7 project, open the  
HW Config configuration tool. 
2.  
In the module catalog, select the 
SIMATIC Technology-CPU profile 
and insert a Rack, optionally a 
power supply and explicitly a 
Technology CPU into your project. 
3.  
 
Acknowledge the message on the 
baud rate by clicking OK. 
4.  
 
Address 2 is assigned to the CPU. 
Create a new DP(Drive) subnet 
using the New button. 
5.  
Set a transmission rate of 
12 MBaud for the DP(Drive) and set 
the DP profile. 
Subsequently select further settings 
for the DP(Drive) using the 
Options… button.