Description of Options
Engineering Information
SINAMICS Engineering Manual – November 2015
Ó Siemens AG
496/528
The TM150 Terminal Module does not provide electrical isolation between its inputs for temperature sensors and the
electronic evaluation circuit. As a result, temperature sensors may be connected only if they are at ground potential
or comply with the safety isolation requirements defined by EN 61800-5-1.
Design
The TM150 Terminal Module features the following components:
· 6/12 temperature sensor inputs (depending on connection type) for KTY84-130, PT1000, PT100, PTC or
bimetallic NC contact (evaluation can be parameterized for a circuit with 1x2 wires, 2x2 wires, 3 wires or 4
wires for each terminal block)
· 2 DRIVE-CLiQ sockets
· 1 connection for the electronics power supply via the 24 V DC supply connector
· 1 PE/protective conductor connection
The TM150 Terminal Module is designed to be snapped onto a standard DIN rail TH 35 compliant with EN 60715
(IEC 60715).
The signal cable shield can be connected at the TM150 Terminal Module by means of a terminal clamp, e.g. of type
SK8 supplied by Phoenix Contact or type KLBÜ CO 1 supplied by Weidmüller.
The status of the TM150 Terminal Module is indicated by a multi-color LED.
Technical data
TM150 Terminal Module
6SL3055-0AA00-3LA0
Power demand, typ. / max.
at 24 V DC
Approx. 0.1 A / 0.5 A
• Connection cross-section, max.
2.5 mm
2
• Fuse protection, max.
20 A
Temperature sensor inputs
The following temperature sensors can be evaluated at the inputs:
KTY84-130, PT1000, PT100, PTC or bimetallic NC contact.
The inputs of each terminal block can be parameterized to evaluate
1x2 wires, 2x2 wires, 3 wires or 4 wires.
• Permissible temperature range -99°C to +250°C
• Connection cross-section, max.
1.5 mm
2
• Current per sensor, approx.
0.8 mA
• Safe isolation according to EN 61800-5-1
No
Power loss
< 10 W
PE connection M4 screw
Dimensions
• Width
• Height
• Depth
30 mm
150 mm (+ shield connecting plate 28 mm)
119 mm
Weight approx. 0.41 kg
Conformity CE