01.02 1 Alarms
© Siemens AG 2002 All Rights Reserved 6FC5598-3AA20-0BP2
SINUMERIK 802S/802C (DG) 1-35
Alarm display.
Interface signals are set.
Corrected block.
Study Programming Instructions and machine data with refer to the really con-
figured addresses and their meaning and correct the NC block accordingly.
Press NC START to clear the alarm and continue program execution.
Channel %1 block %2 same G group programmed repeatedly
%1 = Channel number
%2 = Block number, label
The G functions that can be used in the part program are divided into groups
which are syntax-defining or non syntax-defining. Only one G function each
from each G group may be programmed. The functions within a group are
mutually exclusive.
The alarm concerns only the non-syntax defining G functions. If several G
functions from these groups are called in an NC block, the last function of a
group will be active (all previous functions are ignored).
G FUNCTIONS:
Syntax-defining G functions Non-syntax defining G functions
1st to 4th G group 5th to nth G group
Alarm display.
Interface signals are set.
No remedial action necessary. However, it should be checked whether the last
programmed G function is really the desired one.
Press NC START to clear the alarm and continue program execution.
Channel %1 block %2 too many syntax-defining G functions
%1 = Channel number
%2 = Block number, label
Syntax-defining G functions define the structure of the part program block
and of the addresses contained in it. Only one syntax-defining G function may
be programmed in an NC block. The G functions of the 1st to 4th G group are
syntax-defining.
Alarm display.
Interface signals are set.
Corrected block.
Analyze the NC block and distribute the G functions over several NC blocks.
Press NC START to clear the alarm and continue program execution.
Response
Remedy
Program continua-
tion by
12 060
Explanation
Response
Remedy
Program continua-
tion by
12 070
Explanation
Response
Remedy
Program continua-
tion by

Other manuals for Siemens SINUMERIK 802C

Related product manuals