01.02 1 Alarms
© Siemens AG 2002 All Rights Reserved 6FC5598-3AA20-0BP2
SINUMERIK 802S/802C (DG) 1-67
Channel %1 block %2 value violates lower limit
%1 = Channel number
%2 = Block number, label
You have tried to write into an MD with a value less than the defined lower
limit.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Determine the input limits of the MD and carry out value assignment within
these limits.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 value violates upper limit
%1 = Channel number
%2 = Block number, label
You have tried to write into an MD with a value greater than the defined upper
limit.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Determine the input limits of the MD and carry out value assignment within
these limits.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 tool is not selected
%1 = Channel number
%2 = Block number, label
You have tried to access the current tool compensation data although no tool
has been selected.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Program or activate a tool compensation in the NC part program.
Example:
N100 G. .. T5 D1 .. LF
Press the RESET key to clear the alarm. Restart part program.
17 080
Explanation
Response
Remedy
Program continua-
tion by
17 090
Explanation
Response
Remedy
Program continua-
tion by
17 160
Explanation
Response
Remedy
Program continua-
tion by