PLC alarms
11/2006 Overview of Alarms
2-821
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
400602 Spindle configuration incorrect
Definitions: The PLC configuration in the DB4 does not match the NC configuration
Reaction: Alarm display.
Remedy: Correct tool management start-up
Program
Continuation:
Switch control OFF - ON.
400603 Revolver configuration incorrect
Definitions: The PLC configuration in the DB4 does not match the NC configuration
Reaction: Alarm display.
Remedy: Correct tool management start-up
Program
Continuation:
Switch control OFF - ON.
400604 Set change with M06 in the machine data
Definitions: With the magazine type used (box magazine, chain), changing is possible only with M06. If necessary,
also check for impermissible settings at revolver magazines.
Reaction: Alarm display.
Remedy: Set the value in the channel-specific machine data TOOL_CHANGE_MODE (MD 22550) to 1.
Program
Continuation:
Internal
400902 Parameter ChanNo impermissible in FC 9
Definitions: The parameterized channel does not exist.
Reaction: Alarm display.
Remedy: Correct the parameter.
Program
Continuation:
Switch control OFF - ON.
400903 Parameter IntNo impermissible in FC 9
Definitions: The parameterized interrupt does not exist.
Reaction: Alarm display.
Remedy: Correct the parameter.
Program
Continuation:
Switch control OFF - ON.
401003 FC 10 system error 0x8083
Definitions: System error SFC52 has occurred.
Reaction: Alarm display.
Remedy: Restart, contact the Siemens AG A&D MC Hotline with the error text.
Program
Continuation:
Switch control OFF - ON.
401004 FC 10 system error 0x8084
Definitions: System error SFC52 has occurred.
Reaction: Alarm display.
Remedy: Restart, contact the Siemens AG A&D MC Hotline with the error text.
Program
Continuation:
Switch control OFF - ON.