Overview of Alarms 11/2006
PLC alarms
2-822
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
401005 FC 10 system error 0x8085
Definitions: System error SFC52 has occurred.
Reaction: Alarm display.
Remedy: Restart, contact the Siemens AG A&D MC Hotline with the error text.
Program
Continuation:
Switch control OFF - ON.
401006 FC 10 system error 0x8086
Definitions: System error SFC52 has occurred.
Reaction: Alarm display.
Remedy: Restart, contact the Siemens AG A&D MC Hotline with the error text.
Program
Continuation:
Switch control OFF - ON.
401007 FC 10 system error 0x8087
Definitions: System error SFC52 has occurred.
Reaction: Alarm display.
Remedy: Restart, contact the Siemens AG A&D MC Hotline with the error text.
Program
Continuation:
Switch control OFF - ON.
401502 Impermissible axis no. parameter in FC 15
Definitions: The parameterized axis does not exist.
Reaction: Alarm display.
Remedy: Correct the parameter.
Program
Continuation:
Switch control OFF - ON.
401602 Impermissible axis no. parameter in FC 16
Definitions: The parameterized axis does not exist.
Reaction: Alarm display.
Remedy: Correct the parameter.
Program
Continuation:
Switch control OFF - ON.
401702 Impermissible spindle IF no. parameter in FC 17
Definitions: The parameterized spindle does not exist.
Reaction: Alarm display.
Remedy: Correct the parameter.
Program
Continuation:
Switch control OFF - ON.
401805 Impermissible axis no. parameter in FC 18
Definitions: The parameterized axis / spindle does not exist.
Reaction: Alarm display.
Remedy: Correct the parameter.
Program
Continuation:
Switch control OFF - ON.