Commissioning HMI Advanced (IM4) 08/2005
2 Functions/Parameterization
© Siemens AG, 2005. All rights reserved
IM4/2-124 SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
2.6.2 Simulation Data Display
The files loaded into the simulation are displayed with softkey Match data →
Loaded data.
User programs
All programs currently copied into the simulation are displayed. They are deleted
from the simulation again when a different workpiece is selected.
Changes to these programs via the compensation editor are made directly in the
HMI or NCK, and the modified programs are automatically copied into the
simulation. If these programs are modified externally (e.g. via Services), the
change is detected at the time of the next simulation selection and the programs
concerned are copied into the simulation.
If files exist for the current workpiece (extension RPA, GUD, SEA, UFR, PRO,
CEC, TOA, TMA), they are loaded into the simulation when the workpiece is
selected. These files are retained when the workpiece is changed and their date
stamp is monitored.
If these files are modified externally (e.g. via Services/Programs), the change is
detected at the time of the next simulation selection and the files concerned are
automatically loaded into the passive file system for the simulation.
User cycles
All user cycles loaded into the simulation are displayed. If the cycles have not been
loaded before, the cycle interfaces must be defined in the file DPCUSCYC.COM.
The cycles are then copied into the simulation when required. Changes to the
cycles are not detected automatically and must be detected by means of the
"Match cycles" softkey.
All user cycles loaded into the simulation are displayed.
Manufacturer cycles
All manufacturer cycles loaded into the simulation are displayed. If the cycles have
not been loaded before, the cycle interfaces must be defined in the file
DPCUSCYC.COM. The cycles are then copied into the simulation when required.
Changes to the cycles are not detected automatically and must be detected by
means of the "Match cycles" softkey.
All manufacturer cycles loaded into the simulation are displayed.
Standard cycles
All standard cycles loaded into the simulation are displayed. The cycles are then
copied into the simulation when required. Changes to the cycles are not detected
automatically and must be detected by means of the "Match cycles" softkey.
All user cycles loaded into the simulation are displayed.

Table of Contents

Other manuals for Siemens Sinumerik 840 sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840 sl and is the answer not in the manual?

Siemens Sinumerik 840 sl Specifications

General IconGeneral
BrandSiemens
ModelSinumerik 840 sl
CategoryControl Unit
LanguageEnglish

Related product manuals