Overview of Alarms 08/2005
2-14
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
1002 System error %1
Parameters: %1 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions: - Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
1003 Alarm pointer for this self-clearing alarm %1 is zero
Parameters: %1 = Incorrect alarm number
Definitions: The address (zero pointer) used by the compile cycle manufacturer or by the operating
system for self-clearing alarms is not allowed in the system.
Reactions: - Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Check setCCAlarm/setAlarm (...) call.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
1004 Alarm reaction to NCK alarm incorrectly configured
Parameters: %1 = Incorrect alarm number
Definitions: The alarm reaction configured by the operating system or the compile cycles manufac-
turer is incorrect.
Reactions: - NC not ready.
- Channel not ready.
- Interface signals are set.
- Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Change alarm reaction
Program Con-
tinuation:
Switch control OFF - ON.
1005 Operating system error %1 parameter %2 %3 %4
Parameters: %1 = Operating system error number
%2 = Operating system error parameter 1
%3 = Operating system error parameter 2
%4 = Operating system error parameter 3
Definitions: This alarm indicates that the operating system has detected a serious error.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
tinuation:
Switch control OFF - ON.