Overview of Alarms 08/2005
2-22
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
2140 The actual service switch position forces the SRAM to be cleared at the next Power
On (general reset active)
Definitions: The initialization switch is currently set to overall reset. This means that the module's
SRAM is deleted with the next module reset. The NC data memory is cleared during this
operation.
Reactions: - NC not ready.
- Interface signals are set.
- Alarm display.
Remedy: Reset initialization switch to zero.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
2190 Hardware plug-in module for communication with the digitizer missing
Definitions: MD $MN_ASSIGN_DIGITIZE_TO_CHAN was used to activate the digitizing function by
assigning it to a channel. The function requires a hardware module (RS422 board
plugged into the NCU) for communication with the digitizing unit. This module was not
found when booting.
Reactions: - Interface signals are set.
- Alarm display.
Remedy: Please inform the authorized personnel/service department. Plug in communications
module or cancel channel assignment.
Program Con-
tinuation:
Switch control OFF - ON.
2192 No NCU link module exists, MD %1 reset
Parameters: %1 = String: MD identifier
Definitions: An attempt was made to activate the NCU link functionality but the hardware is not avail-
able. The MD was reset. Only occurs with the NCU link system
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Install the hardware module and activate the function again (MD).
Program Con-
tinuation:
Switch control OFF - ON.
2193 'Safety Integrated' is not available for link axis %1.
Parameters: %1 = Machine axis index
Definitions: The "Safety Integrated" function is not available for a link axis. Only occurs with the NCU
link system
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Use "Safety Integrated" function for local axes only.
Program Con-
tinuation:
Switch control OFF - ON.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes