Overview of Alarms 08/2005
2-28
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Parameters: %1 = Axis
%2 = String: MD identifier
Definitions: Machine axes which can be activated on several NCKs through
$MN_AXCONF_LOGIC_MACHAX_TAB must be assigned to a master NCU in
$MA_AXCONF_ASSIGN_MASTER_NCU. For axes that are activated on only one NCU,
the number of this NCU or zero must be entered as master NCU. An assignment can only
be made with MA_AXCONF_ASSIGN_MASTER_NCU if the machine axis is also
addressed via a channel
($MC_AXCONF_MACHAX_USED+$MN_AXCONF_LOGIC_MACHAX_TAB).
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Correct $MA_AXCONF_ASSIGN_MASTER_NCU and/or
$MN_AXCONF_LOGIC_MACHAX_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4010 Invalid identifier used in machine data %1[%2]
Parameters: %1 = String: MD identifier
%2 = Index: MD array
Definitions: When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,
Richtungsvektoren, direction vectors, interpolation parameters and intermediate point
coordinates, one of the following syntax rules for the identifier to be entered has been vio-
lated:
• The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly
with a numerical extension (840D: 1-99, FM-NC: 1-9)
• The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for sys-
tem variable).
• The identifier must not be a keyword of the NC language (e.g. POSA).
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Enter the identifier for user-
defined names with correct syntax in the displayed MD.
• Machine axes: AXCONF_MACHAX_NAME_TAB
• Euler angles: EULER_ANGLE_NAME_TAB
• Normal vectors: NORMAL_VECTOR_NAME_TAB
• Direction vectors: 10640 DIR_VECTOR_NAME_TAB
• Interpolation parameters: 10650 IPO_PARAM_NAME_TAB
• Intermediate point coordinates: 10660 INTERMEDIATE_POINT_NAME_TAB
Program Con-
tinuation:
Switch control OFF - ON.
4011 Channel %1 invalid identifier used in machine data %2[%3]
Parameters: %1 = Channel number
%2 = String: MD identifier

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes