Overview of Alarms 08/2005
2-38
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
%3 = String: MD identifier
Definitions: Using the specified machine data %2 leads to a conflict with machine data %3.
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Correct the specified machine data.
Program Con-
tinuation:
Switch control OFF - ON.
4050 NC code identifier %1 cannot be reconfigured to %2
Parameters: %1 = String: Old identifier
%2 = String: New identifier
Definitions: Renaming of an NC code was not possible for one of the following reasons:
• The old identifier does not exist
• The new identifier is within another type range.
NC codes/keywords can be reconfigured as long as you stay within the type range.
Type 1: "true" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: addresses which can be set: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Correct machine data 10712:
NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified Following odd address: New identifier
e.g.: NC_USER_CODE_CONF_NAME_TAB [10] = "ROT",
NC_USER_CODE_CONF_NAME_TAB [11] = " " clears the ROT function from the control
Program Con-
tinuation:
Switch control OFF - ON.
4060 Standard machine data loaded
Definitions: The standard MD were loaded because
• a cold start was requested or
• the MD buffer voltage failed or
• an initialization was requested for loading the standard machine data (MD 11200
INIT_MD).
Reactions: - Alarm display.
Remedy: Please inform the authorized personnel/service department. After automatically loading
the standard MDs, the individual MDs must be entered or loaded in the relevant system.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4062 Backup data loaded

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes

Related product manuals