Overview of Alarms 08/2005
2-44
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4113 Sysclock cycle changed to %1 ms
Parameters: %1 = String (new PLC cycle time)
Definitions: MD 10050 SYSCLOCK_CYCLE_TIME has been modified on systems with PROFIBUS
DP because of the modified DP cycle in SDB1000.
Reactions: - Alarm display.
Remedy: Machine data 10050 SYSCLOCK_CYCLE_TIME has been modified.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4114 Error in DP cycle of SDB1000
Parameters: %1 = String (new PLC cycle time)
Definitions: The DP cycle in SDB1000 contains an error and cannot be set. The default value of
$MN_SYSCLOCK_CYCLE_TIME is set.
Reactions: - Alarm display.
Remedy: Correct SDB1000
Program Con-
tinuation:
Switch control OFF - ON.
4115 Time ratio communication to Ipo changed to %1
Parameters: %1 = String (new PLC cycle time)
Definitions: The value of the machine data 10072 has been adapted. This can only occur, if the value
of the machine data is smaller than one and the time thus calculated is no multiple of the
position control cycle.
Reactions: - Alarm display.
Remedy: The machine data $MN_COM_IPO_TIME_RATIO has been adapted. Please check to
ensure that the calculated value is correct.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4150 Channel %1 invalid M function subprogram call configured
Parameters: %1 = Channel number
Definitions: The machine data $MN_M_NO_FCT_CYCLE[n] or $MN_M_NO_FCT_CYCLE_PAR con-
tains invalid configration data: An M function, which is used by the system and can not be
replaced by a subprogram call has been specified in the machine data
$MN_M_NO_FCT_CYCLE[n] for the configuration of the subprogram call via M function:
• M0 to M5,
• M17, M30,
• M19, M40 to M45,
• M function for selecting spindle/axis mode according to
$MC_SPIND_RIGID_TAPPING_M_NR (default: M70),
• M functions for nibbling/punching as configured in $MC_NIBBLE_PUNCH_CODE if acti-
vated by $MC_PUNCHNIB_ACTIVATION.
• Also M96 to M99 for applied external language ($MN_MM_EXTERN_LANGUAGE).
The machine data $MN_M_NO_FCT_CYCLE_PAR contains an invalid array index of
$MN_M_NO_FCT_CYCLE[n]. Currently, the values 0 to 9 are permissible. The affected
machine data is reset to the default value -1. This deactivates the function.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes