Overview of Alarms 08/2005
2-52
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
%2 = String: MD identifier
%3 = No. of output
Definitions: The specified machine data assign two NC functions to the same digital/analog output.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Correct machine data.
Program Con-
tinuation:
Switch control OFF - ON.
4280 Assignment of NCK input/output byte via MD %1[%2] does not match hardware
configuration
Parameters: %1 = String: MD identifier
%2 = Index: MD array
Definitions: When booting, the required input/output module was not found at the slot specified in the
MD.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Check hardware and correct
the MD if necessary. Note: Monitoring of the hardware configuration is performed inde-
pendently of the number of activated inputs/outputs (MD 10300 - 10360
FASTIO_ANA(DIG)_NUM_INPUTS(OUTPUTS))
Program Con-
tinuation:
Switch control OFF - ON.
4282 Hardware of external NCK outputs assigned repeatedly
Definitions: Several outputs have been configured on the same hardware byte.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Alter MD 10364
HW_ASSIGN_DIG_FASTOUT or MD 10364 HW_ASSIGN_ANA_FASTOUT.
Program Con-
tinuation:
Switch control OFF - ON.
4285 Error on terminal block %1, error code %2
Parameters: %1 = Number of terminal block (1 ... 4)
%2 = Error code
Definitions: An error occurred on terminal block no. %1 (sign-of-life failure, I/O module removed in
current operation, etc.). All possible errors which can lead to this alarm are not yet known

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes