Overview of Alarms 08/2005
2-54
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Reactions: - Alarm display.
Remedy: Reset MD 30450 IS_CONCURRENT_POS_AX for the axis concerned.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4310 Declaration in MD %1 index %2 is not allowed.
Parameters: %1 = String: MD identifier
%2 = Index: MD array
Definitions: The machine data values must be written in the array in ascending order.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Correct the MD.
Program Con-
tinuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
4320 Axis %1 function %2 %3 and %4 not allowed
Parameters: %1 = String: Axis identifier
%2 = String: MD identifier
%3 = String: Bit
%4 = String: MD identifier
Definitions: The functions declared by the specified machine data cannot simultaneously be active for
one axis.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Deactivate one of the functions.
Program Con-
tinuation:
Switch control OFF - ON.
4334 Channel %1 The amount of fine correction in parameter %2 of the orientable tool-
holder %3 is too large
Parameters: %1 = Channel number
%2 = Invalid parameter of the orientable toolholder
%3 = Number of the orientable toolholder
Definitions: The maximum permissible value of the fine correction in an orientable toolholder is limited
by the machine data $MC_TOCARR_FINE_LIM_LIN for linear variables, and by the
machine data $MC_TOCARR_FINE_LIM_ROT for rotary variables. The alarm can only
occur if the setting data $SC_TOCARR_FINE_CORRECTION is not equal to zero.
Reactions: - Correction block is reorganized.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Remedy: Enter a valid fine correction value.