08/2005 Overview of Alarms
2-63
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Reactions: - Alarm display.
Remedy: Reasons for the message:
• The NCK contains compile cycle software, that uses so much memory space that the
hardware cannot provide the required memory.
• The NCK runs on hardware that is not intended for this NCK release (i.e. that has not
enough memory capacity).
• If the application runs properly with the remaining free user memory (i.e. can be started
up without any errors), the message can simply be ignored.
• If the actual application cannot be configured because there is not enough memory
capacity available, either the existing compile cycle must be reduced or, if possible, the
system must be upgraded with additional memory space.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
6100 Error while creating %1, error number %2 %3
Parameters: %1 = Symbolname
%2 = Error code
%3 = If required, internal error identifier
Definitions: An error was detected while creating a compile cycle machine data. The error number
specifies the type of error.
• Error number 1: Insufficient memory available
• Error number 2: Symbol in the NCK already exists
• Error number 3: Maximum possible number of symbols exceeded
• Error number 4: Invalid name prefix
• Error number 5: Illegal array size
Note: Other errors of this type could have occurred, but have not been displayed.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: • Error number 1: The memory reserved by machine data 12328
$MN_MM_CC_MD_MEM_SIZE has to be increased. If the error occurs while loading an
archive, then the machine data must be increased "manually". To do this, either Edit the
archive with 'arcedit' or Overwrite the MD in the MD picture and prevent the deletion of the
machine data when writing the archive (MMC: Set Ask_for_CFG_RESET.INI = 1 in
'dino.ini'). Also refer to: Upgrade instructions P6.x.
• Error number 2: Error in the combination or while reloading compile cycles: Do not acti-
vate compile cycle.
• Error number 3: Error in the combination or while reloading compile cycles: Do not acti-
vate compile cycle.
• Error number 4: Error in the compile cycle: Do not activate compile cycle.
• Error number 5: Error in the compile cycle: Do not activate compile cycle.
Program Con-
tinuation:
Switch control OFF - ON.
6200 Memory for CC MD full.
Definitions: The memory reserved for storage of compile cycle machine data is full.
Some of these machine data could not be created correctly.
Reactions: - Alarm display.
Remedy: Please inform the authorized personnel/service department.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes