Overview of Alarms 08/2005
2-946
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
411101 Impermissible Parameter Axis in FB11
Definitions: Axis parameter not within the permissible range.
Reactions: - Alarm display.
Remedy: Use permissible axis number.
Program Con-
tinuation:
Internal
411501 Incorrect version of FB 15, > general reset, do not transmit FB 15 from project
Definitions: FB 15 does not match the basic program used.
Reactions: - Alarm display.
Remedy: General PLC reset. Use correct version of the basic program.
Program Con-
tinuation:
Internal
411502 Incorrect basic PLC program version
Definitions: FB 15 does not match the basic program used.
Reactions: - Alarm display.
Remedy: Load the basic program that matches the NCK version.
Program Con-
tinuation:
Internal
800000 Error: HiGraph group no. %A graph no. %N status %Z
Definitions: -
Reactions: - Alarm display.
Remedy: -
Program Con-
tinuation:
Internal
810001 Error OB event, error analysis via STEP7 required
Definitions: Reduced PLC error message. STEP7 is required for exact analysis.
Reactions: - Alarm display.
Remedy: Diagnose with STEP7.
Program Con-
tinuation:
Internal
810002 Synchronous error, error analysis via STEP7 required
Definitions: Reduced PLC error message. STEP7 is required for exact analysis.
Reactions: - Alarm display.
Remedy: Diagnose with STEP7.
Program Con-
tinuation:
Internal
810003 Asynchronous error, error analysis via STEP7 required
Definitions: Reduced PLC error message. STEP7 is required for exact analysis.
Reactions: - Alarm display.
Remedy: Diagnose with STEP7.
Program Con-
tinuation:
Internal
810004 Stop/abort event, error analysis via STEP7 required
Definitions: Reduced PLC error message. STEP7 is required for exact analysis.