Page #956 background imageLoading...
Page #956 background image
List of Action Numbers 08/2005
3-956
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 31
No. 32
No. 33
No. 34
No. 35
Explanation Stop the JOG motion (VDI signal: NC Stop)
Not allowed if -
Remedy -
Explanation Stop digitizing processing (VDI signal: NC Stop).
Not allowed if -
Remedy -
Explanation Start selected processing (VDI signal: NC Start).
Not allowed if Process change active (operating mode change, activate/deactivate digitizing/overstore)
An alarm reaction is pending which prevents a start or forces braking.
A process is running (NC program, block search, loading machine data)
Remedy Execute condition for clearing alarm
Explanation Stop the active processing (VDI signal: NC Stop).
Not allowed if -
Remedy -
Explanation Start machine data processing (INI file is already in the NCK)
(PI command).
Not allowed if -
Remedy -

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes

Related product manuals