Error code 0017H
Error text SCI interrupt
Extension 1 -
Extension 2 -
Explanation An illegal processor interrupt has occurred.
The cause is probably a hardware error on the control module.
Remedy Check the drive bus cable and cable connections. Replace the control module.
Error code 0018H
Error text HOST interrupt
Extension 1 -
Extension 2 -
Explanation An illegal processor interrupt has occurred.
The cause is probably a hardware error on the control module.
Remedy Check the drive bus cable and cable connections. Replace the control module.
Error code 0019H
Error text DSP-NMI (10 V at pin IRQB of the DPS)
Extension 1 -
Extension 2 -
Explanation An illegal processor interrupt has occurred.
The cause is probably a hardware error on the control module.
Remedy Check the drive bus cable and cable connections. Replace the control module.
Error code 001BH
Error text Actual current measurement starting.
Extension 1 0 : Deviation from current 0
1 : Module selection does not match the existing hardware (V 2.6 and higher).