System Reactions on Alarms 08/2005
Cancel criteria for alarms
5-990
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
5.1 Cancel criteria for alarms
Names CANCELCLEAR
Effect The alarm is cleared by pressing the Cancel key in any channel. It is also cleared by the
Start part program key.
− Clear the alarm with the Clear key or with NC START
Names CLEARHIMSELF
Effect Self-clearing alarm. The alarm is cleared not by an operator action but explicitly by a
"clearAlarm" in programmed the NCK source code.
− Alarm display disappears with alarm cause. No further operator action necessary.
Names NCSTARTCLEAR
Effect The alarm is cleared by starting a program in the channel, in which the alarm occurred.
The alarm is also cleared by an NC reset.
− Clear the alarm with NC START or the RESET key and continue the program.
Names POWERONCLEAR
Effect The alarm is canceled by turning off / turning on the control system (POWER ON).
− Switch the control OFF - ON.
Names RESETCLEAR
Effect The alarm is cleared by pressing the Reset key in the channel in which the alarm
occurred.
− Clear alarm with the RESET key. Restart part program.
Names BAGRESETCLEAR
Effect The alarm is cleared by a "BAGRESETCLEAR" command or by carrying out a reset in
all channels of this mode group.
− Press the RESET key to clear the alarm in all channels of this mode group. Restart
part program.
Names NCKRESETCLEAR
Effect The alarm is cleared by an "NCKRESETCLEAR" command or by carrying out a reset in
all channels.
− Clear alarm in all channels with the RESET key. Restart part program.
Names NOCLEAR
Effect The clear information is only required for the internal pseudo alarm number
EXBSAL_NOMOREALARMS.