Overview of Alarms 03/2009
NCK alarms
2-30
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Check axis configuration and enter the missing identifier into the MD or, should the axis not exist,
specify for this channel axis the machine axis 0 in the channel-specific MD20070
$MC_AXCONF_MACHAX_USED. If this concerns a geometry axis that is not to be used (this applies
only for 2-axis machining, e.g. on lathes), then channel axis 0 must be entered additionally in the chan-
nel-specific MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4031 [Channel %1: ] Link axis %2 defined for more than one channel in
machine data %3
Parameters: %1 = Channel number
%2 = Index: Axis number for logical axis assignment
%3 = String: MD identifier
Definitions: -
Reaction: NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Correct the MD20070 $MC_AXCONF_MACHAX_USED or assign a master channel. In the event of
a link communication failure, these error causes have to be remedied first.
Program Con-
tinuation:
Switch control OFF - ON.
4032 [Channel %1: ] Wrong identifier for facing axis in %2
Parameters: %1 = Channel number
%2 = String: MD identifier
Definitions: According to the axis configuration in MD20150 $MC_GCODE_RESET_VALUES or MD20100
$MC_DIAMETER_AX_DEF, a facing axis identifier is expected at the specified location.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Add the correct identifier.
Program Con-
tinuation:
Switch control OFF - ON.