Overview of Alarms 08/2005
2-14
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
1002 System error %1
Parameters: %1 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions: - Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
1003 Alarm pointer for this self-clearing alarm %1 is zero
Parameters: %1 = Incorrect alarm number
Definitions: The address (zero pointer) used by the compile cycle manufacturer or by the operating
system for self-clearing alarms is not allowed in the system.
Reactions: - Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Check setCCAlarm/setAlarm (...) call.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
1004 Alarm reaction to NCK alarm incorrectly configured
Parameters: %1 = Incorrect alarm number
Definitions: The alarm reaction configured by the operating system or the compile cycles manufac-
turer is incorrect.
Reactions: - NC not ready.
- Channel not ready.
- Interface signals are set.
- Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Change alarm reaction
Program Con-
tinuation:
Switch control OFF - ON.
1005 Operating system error %1 parameter %2 %3 %4
Parameters: %1 = Operating system error number
%2 = Operating system error parameter 1
%3 = Operating system error parameter 2
%4 = Operating system error parameter 3
Definitions: This alarm indicates that the operating system has detected a serious error.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
tinuation:
Switch control OFF - ON.

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based