08/2005 Overview of Alarms
2-79
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
6690 Cycles from NC card cannot be copied to the passive file system.
Definitions: There is not enough space in the file system that the directories specified in the
$PCMCIA_FUNKTION_MASK can be copied from the NC card to the passive file system.
Reactions: - Alarm display.
Remedy: Delete data in the file system.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6691 Cycles from the passive file system cannot be saved on the NC card
Definitions: There is not enough space on the NC card that the directories specified in the
$PCMCIA_FUNKTION_MASK can be saved. It is possible that cycles are lost during the
next booting.
Reactions: - Alarm display.
Remedy: Delete data on the NC card or delete cycles not required.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6692 Cycle %1 lost
Parameters: %1 = Name of cycle
Definitions: A cycle has been changed and due to a power failure, the backup on the PC card could
not be terminated properly. The cycle is lost.
Reactions: - NC not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy: Import the cycle again.
Program Con-
tinuation:
Switch control OFF - ON.
6693 File %1 lost
Parameters: %1 = Name of file
Definitions: Due to a power failure, a file change could not be terminated properly. The file is lost.
Reactions: - NC not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy: Import the file again.
Program Con-
tinuation:
Switch control OFF - ON.
6698 Unknown NC card (%1/%2). Writing not possible.
Parameters: %1 = actManufactorCode (manufacturer code read by the card)
%2 = actDeviceCode (memory code read by the card)
Definitions: The NC card cannot be accessed because a valid write algorithm is not available for the
flash memory.
Reactions: - Alarm display.
Remedy: Use a compatible NC card or enter the new manufacturer code/device code in MD
$MN_PERMISSIVE_FLASH_TAB after consultation with SIEMENS.