Overview of Alarms 08/2005
2-876
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Current setpoint filter 2:
MD 1215 <= 2 * MD 1213
Current setpoint filter 3:
MD 1218 <= 2 * MD 1216
Current setpoint filter 4:
MD 1221 <= 2 * MD 1219
Speed setpoint filter 1:
MD 1516 <= 2 * MD 1514
Speed setpoint filter 2:
MD 1519 <= 2 * MD 1517
Modify MD 1212: $MD_CURRENT_FILTER_1_BW_NUM (numerator bandwidth cur-
rent setpoint filter 1)
Modify MD 1210: $MD_CURRENT_FILTER_1_SUPPR_FREQ (suppression frequency
current setpoint filter 1)
Modify MD 1215: $MD_CURRENT_FILTER_2_BW_NUM (numerator bandwidth current
setpoint filter 2)
Modify MD 1213: $MD_CURRENT_FILTER_2_SUPPR_FREQ (suppression frequency
current setpoint filter 2)
Modify MD 1218: $MD_CURRENT_FILTER_3_BW_NUM (numerator bandwidth current
setpoint filter 3)
Modify MD 1216: $MD_CURRENT_FILTER_3_SUPPR_FREQ (suppression frequency
current setpoint filter 3)
MD1221: $MD_CURRENT_FILTER_4_BW_NUM (numerator bandwidth current set-
point filter 4)
Modify MD 1219: $MD_CURRENT_FILTER_4_SUPPR_FREQ (suppression frequency
current setpoint filter 4)
Modify MD 1516: $MD_SPEED_FILTER_1_BW_NUMERATOR (numerator bandwidth
speed setpoint filter 1)
Modify MD 1514: $MD_SPEED_FILTER_1_SUPPR_FREQ (suppression frequency
speed setpoint filter 1)
Modify MD 1519: $MD_SPEED_FILTER_2_BW_NUMERATOR (numerator bandwidth
speed setpoint filter 2)
Modify MD 1517: $MD_SPEED_FILTER_2_SUPPR_FREQ (suppression frequency
speed setpoint filter 2)
Program Con-
tinuation:
Clear alarm with the RESET key in all channels. Restart part program.
300769 Axis %1 drive %2 denominator bandwidth > double natural frequency
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The bandwidth denominator of a current or speed setpoint filter is greater than twice the
natural frequency.
This error message is only issued for the general bandstop filter if:
Speed setpoint filter 1:
MD 1516 > 0.0 or
MD 1520 <> 100.0
Speed setpoint filter 2:
MD 1519 > 0.0 or
MD 1521 <> 100.0
Current setpoint filter 1:
MD 1212 > 0.0